Thermoplastic Modular System

Specifications

  1. Apply AP-1200 EPDM Rinseable Primer to the entire surface at a rate of 300 – 400 square feet per gallon. Allow 10-15 minutes to activate before pressure washing with a minimum of 2000 PSI.
  2. The surface should be clean and dry before the installation of the Armour-Ply System.
  3. Apply one coat of AP-6100 Modified Liquid Rubber Coating at a rate of 1.00 – 1.25 gallons per 100 square feet. Allow 2-6 hours to dry.
  4. Apply a second coat of AP-6100 Modified Liquid Rubber Coating at a rate of 1.00 – 1.25 gallons per 100 square feet. Allow 2-6 hours to dry.

Download Spec Sheet